EantG went down at 05:21:59 UTC. Log file on the ap24eth again mentions "extensive data loss". EantH and EantI (sodar) stayed up.
We power cycled the antenna which brought it back. We also fetched the pocketecs and usb stick from profile, downwind1 and pressure1.
I'm not sure that changing the frequency, as was done earlier, changes anything. After changing the frequency, the Etherants still indicated that they are using channel #1.
Will now try setting the disconnect-timeout parameter to 15 seconds (the maximum allowed value). The default is 3 seconds. Will also increase the on-fail-retry-time to 1/2 second
interface wireless set 1 disconnect-timeouot=15s interface wireless set 1 on-fail-retry-time=500ms
Here are the current wireless interface settings:
1 R name="wlan2-Ext-Ant" mtu=1500 mac-address=00:15:6D:10:3C:BC arp=enabled disable-running-check=no interface-type=Atheros AR5213 radio-name="AP24-ExtAnt" mode=ap-bridge ssid="ISFF14" area="" frequency-mode=manual-txpower country=united states antenna-gain=0 frequency=2462 band=2.4ghz-b/g scan-list=default rate-set=default supported-rates-b=1Mbps,2Mbps,5.5Mbps,11Mbps supported-rates-a/g=6Mbps,9Mbps,12Mbps,18Mbps,24Mbps,36Mbps,48Mbps,54Mbps basic-rates-b=1Mbps basic-rates-a/g=6Mbps max-station-count=50 ack-timeout=dynamic tx-power=25 tx-power-mode=all-rates-fixed noise-floor-threshold=default periodic-calibration=default periodic-calibration-interval=60 burst-time=disabled dfs-mode=radar-detect antenna-mode=ant-a wds-mode=disabled wds-default-bridge=none wds-default-cost=100 wds-cost-range=50-150 wds-ignore-ssid=no update-stats-interval=disabled default-authentication=no default-forwarding=yes default-ap-tx-limit=0 default-client-tx-limit=0 proprietary-extensions=post-2.9.25 hide-ssid=yes security-profile=isffwep disconnect-timeout=15s on-fail-retry-time=500ms preamble-mode=both compression=no allow-sharedkey=no