Log entries with a label of rain.

Tower visit
John and I checked the rain gauge at soilb for clogs at about 12:00am. It was clean. The 2m krypton was cleaned. UPDATE: The gauge did show a tip when a rain event moved through at about 2:00 pm and the 2m krypton went to 0 volts.
rain event
A quick shower came through just before 3:00 pm.
Have started looking at the comparison between the various rain gauges.  In this analysis, I removed [data when the wetness sensor indicated dry conditions?]  There have been several major rain events, but not all sensors were working: Date understory ott.pond tb.pond wxt.pond wetness.…
rain.tb fix long ago
Gordon and I just had this exchange, that I thought should be put in the logbook (even though it relates to an action a while ago): I'm starting to look at the rain gauge comparison. I note a major event on 7 June that was only seen by the OTT. This caused you to change the WXT settings.  For the next 2 days, Tom's daily status messages noted that rain.tb was not reporting, but this comment was dropped on 9 June.  I haven't found a comment about what fix was done to get rain.…
Rain event
15:30 - A rain event lasting about 30minutes past over us.
few sprinkles
Driving back from Jim's, there were drops on our windshield.  The WXT and wetness sensors have seen it.
Rainr.b clogged
10:30  Upon inspection found the tipping bucket tube at soil.b was clogged with ill-defined organic matter. Since the funnel was full, I tried to allow this water to be measured (post-rain), but only was able to get 2--3 tips to register.  Also, this likely would have been an under-report since the funnel's capacity had been exceeded. We have decided that checking for clogs should be a regular maintenance task.
We had noticed that the tipping bucket mount was somewhat shaky.  I have just secured it by a bit of guying.  The bubble level had been out of the outer ring and now is within the inner ring (though not exactly centered).
rain last night
A storm came in from the north last night.  It rained intensely for about 2min while we had dinner in Tuscaloosa.  All gauges saw it at about 2145 with totals: undercanopy: 5.0mm (includes an event earlier in the day) ott: 3.1mm new tipping bucket: 3.1mm pond: 4.3mm Thus, perfect agreement between the 2 new sensors and general agreement between all. All systems stayed up, though all sensors stayed wet overnight.
Noticed tipping bucket at soil.b was clogged.  Un-clogged tube.  All good again.
WXT rain
The rain value from the wxt has been a constant zero: http://www.eol.ucar.edu/isf/projects/SOAS/isfs/qcdata/plots/20130606/precip_20130606.png http://www.eol.ucar.edu/isf/projects/SOAS/isfs/qcdata/plots/20130606/precip_20130606.png The current output message looks like so: 0R0,Dm=103D,Sm=0.8M,Ta=20.5C,Ua=94.2P,Pa=1.0072B,Rc=0.00M,Hc=0.0M,Vs=12.8V\r\n I rserial'd in and displayed the current precip configuration with the "0RU cr lf" command: 0RU,R=00000000&10010000,I=1,U=M,S=M,M=C,Z=A,X=10000,…
May 31 4:50 Tom replaced battery with low voltage (~9V) at soil site B (rain).  The new battery reads 11.9V