Andy INTERCOMPARISON SYSTEM FIELD NOTES, --------- Friday, September 10, 2004 and Monday, September 13, 2004 ------- (CU and HYDRA Times in watch time MST, USGS Time in Datalogger time, AIRCOA A and AIRCOA B time is Prometheus time ) Tank Pressures with Valves Cylinder Closed Open -------- ------- ----- A FA02374 1440 1460 B FA02361 710 1300 C FA02340 1250 1480 AIRCOA A Willow site 16:05 MDT Cycle power. Sampling line 4 when running again. P = 72.046 on low flow, 80.121 on high flow, F = 2.98 volts 22:06:45 Gas A on. Valves 11 and 12 on (fast-flow and guest cal) 22:07:28 V12 off. 22:08:30 P = 72.006, F = 1.560, CO2 = 367.7 - 368.2 22:10:05 Step 3-way to B and valve 12 on 22:10:55 V12 off 22:12:00 P = 72.006, Flow = 1.599, CO2 = 302.7 - 303.0 22:13:27 Step 3-way to C and valve 12 on. 22:14:16 V12 off. 22:15:15 P = 71.979, Flow = 1.591, CO2 = 330.1 - 330.3 22:16:50 "r" to return control Cal cylinders: HS2 = 1660 psig, HS1 = 940, LS1 = 1740, LS2 = 1800 AIRCOA C Willow site 22:22:30 Sampling line 4 when running again. P = 70.874 on low flow, 77.047 on high flow, F = 2.781 volts 22:23:44 Gas A on. Valves 11 and 12 on (fast-flow and guest cal) 22:24:42 V12 off. 22:26:00 P = 70.927, F = 1.422 - 1.429 CO2 = 395.7 - 399.1 22:27:32 Step 3-way to B and valve 12 on 22:28:53 V12 off 22:30:00 P = 70.772 - 70.888, Flow = 1.406 - 1.431, CO2 = 326.2 - 330.5 22:31:59 Step 3-way to C and valve 12 on. 22:23:01 V12 off. 22:24:00 P = 70.846 - 70.861, Flow = 1.390 - 1.415, CO2 = 355.1 - 360.0 22:35:05 "r" to return control Cal cylinders: HS2 (JJ13615) = 1930 psig, HS1 (JJ8174) = 1890, LS1 (JJ3623) = 1760, LS2 (JJ8588) = 1850 Monday, September 13, 2004 HYDRA at Pine Tower (forgot watch so times nebulous -- around 10:30 - 11:00) Connect to 3-way valve with quick connect On line D-S3. Sample Ball Flow = 35. Pump Pressure = 8.1 psi. Switch to gas A. Done adjusting regulator to get Flow = 35, Pressure = 8.2 psi. CO2 = 59.96 - 60.00 um/m. Step 3-way to B. Adjusted regulator to get Flow = 37, Pressure = 8.2 psi. CO2 = 16.42 - 16.49 um/m. Step 3-way to C. Adjusted regulator to Flow = 35, Pressure = 8.2 psi. CO2 = 35.25 - 36.35 um/m. 3-way back to HYDRA. CU Tower 11:45 MDT Switched profile to manual. Toggled C2. 11:48 P = 20.3 psig. 3-way to ICS, Cylinder A 11:52 Step 4-way to B 11:54 Regulator adjusted to get 20.4 psig, CO2 = 1.110 11:56 Step 4-way to C 11:57 Regulator adjusted to get 20.6 psig, CO2 = 1.181 11:59 Toggled C2. CO2 = 1.258 12:00 Back to Auto. USGS Tower 11:11:50 MST Sampling line 2, P = 543.58 11:13:00 Switched 3-way to start ICS, Cylinder A 11:14:30 Adjusted regulator to get 543.58 11:16:30 Step 3-way to B. 11:17:30 Done adjusting regulator to get 545.89 11:19:30 Step 3-way to C. 11:20:30 Done adjusting regulator to get 546.55 11:23:00 Switched 3-way back to sample from towers, line disconnected AIRCOA B Aspen site 18:55:50 Took control. 18:56:30 Open V11, V12. Gas A. Adjust regulator to 10. 18:57:30 P = 77.276, F = 2.882 18:58:00 V12 turned off. 18:59:00 P = 71.027, F = 1.427, CO2 = 389.8 - 390.9 19:00:18 Switch to gas B 19:00:35 V12 on 19:01:22 Close V12 19:02:36 P = 70.933, F = 1.395, CO2 = 319.5 - 320.2 19:03:50 Switch to C 19:03:54 V12 on 19:04:51 V12 off 19:06:09 P = 70.919, F = 1.382, CO2 = 348.7 - 350.3 19:06:50 Return unit control to Prometheus HS2 = 1610, HS1 = 1840, LS1 = 1760, LS2 = 1720