Currently the profile tower has the only remaining 8P card (and it has been working quite well since we improved the voltage level).
Later noticed that port ttyS7 on upwind was not working. Seems that W240025 also has a bad port. Since we want all ports to work on upwind in order to have one available for the 15 pressure system, I did another swap on Jul 8. At 10:20am removed the first emerald card, W249924, from downwind2, installed it on upwind. Took W240025 from upwind and installed it as the first serial board on downwind2.
The data system configuration is now:
name | viper# | box | tower | net link | serial #0 | serial #1 |
profile | 3 | 6 | profile | eantg | 8P W274095 | 8M 240017 |
downwind1 | 6 | 14 | d4 | hub in profile | 8M W249918 | 8M 250043 |
downwind2 | 1 | 13 | d10 | eanth | 8M W240025 | 8M W240036 |
upwind | 2 | 1 | u7 | hub in downwind2 | 8M W249924 |
|
pressure1 | 10 | small | d4 | hub in profile |
|
|
pressure2 | 11 | large | d10 | hub in downwind2 |
|
|
These serial cards have bad ports
SN | bad ports |
---|---|
W240025 | 2(ttyS7) |
W240036 | 1(ttyS6) |
W240025 and W240036 are on downwind2. The configuration on downwind2 skips ports ttyS7 and ttyS14.