Here are the sensor ids of the ParoScientific sensors and the frequency counter board numbers and the input pin numbers.

Note that 7t is on adam id=5 ( pressure1 ) and 7b is on adam id=6 ( pressure2).  Also notice that ids in the 3000's are not at the top height.

pressure1

Location

adam

temperature id

board,pin

pressure id
devices

board,pin

3b

5

2034

0,1

2036

fcntr0 0,1 8

4b

5

2044

0,18

2046

fcntr2 1,3 1

5b

5

2054

1,8

2056

fcntr4 1,5 18

5t

5

2064

2,1

2066

fcntr6 2,7 8

6b

5

2074

2,18

2076

fcntr8 3,9 1

6t

5

3054

3,8

3056 fcntr10,11

3,18

7t

5

3064

4,1

3066

4,8

pressure2

Location

adam

temperature id

board,pin

pressure id

board,pin

7b

6

2084

2086

fcntr0 0,1

7t

5

3064

3066

2086

0,8 fcntr12,13

8b

6

2094

0,18

2096

fcntr2 1,3 1

8t

6

2104

1,8

2106

fcntr4 1,5 18

9b

6

2114

2,1

2116

fcntr6 2,7 8

9t

6

3074

2,18

3076

fcntr8 3,9 1

10b

6

3084

3,8

3086

fcntr10 3,11 18

11b

6

3094

4,1

3096

fcntr12 4,13 8

To display data for a given id, do (this example is for temperature from 3b)

...