Weather: Overcast much of the night. Not much cooling from 4Z onward. Low ~5C.
Cloud base visible on CL-view (ceilometer), 10K-12K feet this morning. (The plots from MLH analysis don't go high enough to capture this)
Profiler power: 0.130mW (at 15:48Z). Good profiler returns overnight.
...
SODAR site: solar trailer battery at xx% 86% (xam 9am LT); . Sodar chirping. [Battery at 90% (2pm LT) after a mostly cloudy morning]
All sensors appear to be operating well, however:
CEILOMETER CL-View screen still shows a warning: (Status: Blower failure; Status: Heater fault; (both blower and heater show "OFF").)
Backup to DVD: backed up both ISS and GAUS site data-managers this morning.
Voyager disk: Bill filled it and I will return it to Boulder. Lou will bring a replacement good through the project end.
449-RIM-without-RASS: Bill created this new mode for continuous RIM winds, not interrupted by RASS. We started this mode at 20:15UT. Will let it run at least overnight. [WIll need to change back well before next IOP]
LOU arrives this evening to join Clayton. Steve departs tomorrow. Good luck LOU!