Code Block
# shut down data systemprocess
adn

# adn powers off port 17, power it back on.
eio 17 1

# start minicom
# The default baud rate of minicom on that port is 9600, which is what the 7500 
# uses after it is sent a break. To set it to 9600 explicitly, use ctrl-A pe.
# Use ctrl-A minicom commands andto turn on local echo (Ee), line wrap (Ww) and send a break(Ff).
# Set bandwidth to 20 and RS232 output frequency to 20.
# Set terminator to 0A (newline):

minicom ttyS17
ctrl-A pe
ctrl-A e
ctrl-A w
ctrl-A f
(Outputs (BW( 20) (RS232 (Freq 20.0)))
ctrl-A f
(Outputs (RS232 (EOL "0A")))
ctrl-A f
(Outputs ?)
ctrl-A q

# minicom should now be finished

# power off port 17
eio 17 0

# aup start data process. This will power itup port up17
aup

# wait a bit, then
ds
ctrl-C


# If the 7500 doesn't respond, try power cycling it:
eio 17 0
eio 17 1