Note that some of the times I entered as 29 jul and some as 31 jul, depending on when the sonic was last moved.
Note2: On 8/6/08 beginning at 10:20PDT, JohnMilitzer, took a second set of readings as noted '2'. These were completed by 14:30PDT. In the middle of the afternoon, it was optically more difficult to see the alignment angle. I also took repeated readings and noticed some variance in those, but used the common value. The enormous difference between our readings is disturbing, although I verified that the data-scope still has a deviation setting of 0.0
| b | b2 |
|
| t | t2 |
|
| u | u-2 |
|
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 134.7 | 130.4 | 4.3 |
|
|
|
|
|
|
|
|
2 | 137.0 | 133.7 | 3.3 |
|
|
|
|
|
|
|
|
3 | 136.0 | 132.4 | 3.6 |
| 137.1 | 133.6 | 3.5 |
| 141.0 | 138.3 | 1.8 |
4 | 136.3 | 132.7 | 3.6 |
| 135.9 | 132.7 | 3.2 |
| 139.0 | 135.2 | 3.8 |
5 | 135.2 | 132.7 | 2.5 |
| 134.4 | 128.1 | 6.3 |
| 139.2 | 135.3 | 3.9 |
6 | 134.6 | 131.1 | 3.5 |
| 134.3 | 130.3 | 4.0 |
| 141.4 | 138.3 | 3.1 |
7 | 135.5 | 131.6 | 3.9 |
| 136.6 | 132.0 | 4.6 |
| 134.6 | 131.4 | 3.2 |
8 | 136.8 | 133.5 | 3.3 |
| 138.3 | 135.1 | 3.2 |
| 136.5 | 132.4 | 4.1 |
9 | 135.3 | 131.7 | 3.6 |
| 137.9 | 133.0 | 4.9 |
| 141.0 | 138.3 | 2.7 |
10 | 134.7 | 132.4 | 2.3 |
| 135.9 | 132.6 | 3.3 |
| 135.8 | 132.7 | 3.1 |
11 | 136.7 | 133.4 | 3.3 |
| 137.0 | 133.2 | 3.8 |
| 134.5 | 131.2 | 3.3 |
12 | 137.2 | 133.4 | 3.8 |
|
|
|
|
|
|
|
|
13 | (4.8's) |
|
|
|
|
|
|
|
|
|
|
| profile | profile2 |
|
---|---|---|---|
1.5 | 135.1 | 132.7 | 2.4 |
3.3 | 137.0 | 134.0 | 3.0 |
4.8 | 136.1 | 132.4 | 3.7 |
5.8 | 138.2 | 129.9 | 8.3 |
7.0 | 136.2 | 128.7 | 7.5 |
8.0 | 137.0 | 127.4 | 9.6 |
NOTE: Sonic U5 s/n 712's upper arm was bent / misaligned with the lower claw when checked on 8/6/08. The value shown is for the lower arm alignment.