Make sure your meteorology nudging style is consistent - i.e. you are calling Specified Dynamics everywhere or Physics-based nudging everywhere. The specific error above occurred when creating a new case with the FCnudged compset, but changing CAM_CONFIG_OPTS=‘-phys cam6 -chem trop_strat_mam4_vbs -age_of_air_trcs -offline_dyn -nlev 32’. Instead, it should be left at: CAM_CONFIG_OPTS: -phys cam6 -chem trop_strat_mam4_vbs -age_of_air_trcs.
(
...
11) Run error - model crash in "shr_reprosum_calc"
The model crashed with an error in the atm.log.*
such as:
Code Block | ||
---|---|---|
| ||
Global flash freq (/s), lightning NOx (TgN/y) = 267.0744 13.8985
SHR_REPROSUM_CALC: Input contains 0.96000E+02 NaNs and 0.00000E+00 INFs on process 0
ERROR: shr_reprosum_calc ERROR: NaNs or INFs in input |
Check which meteorology file the the model was most recently using, then perform an ncdump
on the U, V and T variables to check whether there are missing values. The meteorology file will likely need to be reprocessed.
(12) NetCDF file version error (as of CESM2.2, may be solved in future versions)
If you provide emissions or any input files in NetCDF version 4 (either NetCDF4 or NetCDF4_classic), the model will crash.
...