10/13/13
Summary:
Second IOP on the night of October 11-12

10/11: 
Replaced floor kh2o
Nothing obviously wrong with P.nne.flr, but Sebastian swapped with P.ssw1.flr
Replaced battery at P.sw.flr
Checked battery voltages at all pressure motes on floor.
Finished replacing dessicant in all radiometers

10/12
Measured guy wire tensions.
Recycling power fixed TRH.20m.rim and Rpile.out.far
Gordon diagnosed and fixed problem with power on the serial ports for the
power-monitering motes
ETC.

10/13
FLR kh2o still dropping out.  Is the serializer having problems?

T/RH: T.20m.rim often a little high, but also sometimes in line with others.  When does this occur?
          RH.40m.near and RH.35m.rim perhaps a bit high.
P: ok
csat u,v: ok
csat ldiag: some ldiag > 0 morning of Oct 12
csat w, tc: ok
kh2o: FLR still flaky; FLR fluxes noisy but believable
motes: FAR ok for past 3 days
           NEAR ok for past 3 days
           FLR all off and on; rad currently missing
Wetness: dew or frost night of October 11-12 (IOP)
radiation: ok
Tsoil: Tsoil.4.4cm.near has offset since 10/12 10:50
         Tsoil.2.5cm.flr & far (linear avg) does not fit profile
Gsoil: ok
Qsoil: ok
Cvsoil: ok
2D sonic: Dir.10m.flr at times appears to be off by 180 deg.