9-Oct-12
personnel: JohnM, TomH.
Winds diminished last night and remain low in the morning, possibly a good night/day for the science. Clear throughout the day with seasonally warm temps.
Ingest: Everything remained up throughout the day.
The Flux computer was still running cockpit ok this morning allowing status check. Tom Horst retreived it by 7:30 and took it to Boulder to be rebuilt before the next crew arrives.
The sensors continue to perform well and are coming in. Stations remain up and running. The issues noticed:
a2: 1m CSAT was not having any diag errors because the winds have been low. It was swapped by 10:15MST (16:15Z): s/n 833 removed, s/n 671 installed.
a8: TRH mote data now looking good. Since code update have not seen any \r\n hits.
Mote \r\n Issues: I don't see any/many of these in the data from other stations and now ID8 is running well. A more thorough examination confirmed that really only ID8 was a culprit. That particular mote was a replacement/repair brought up from Boulder after the site had some trh issues. The problem appears resolved.