Jacquie will have us create a data monitoring page, but for set-up/burn-in, I'm going to keep track of issues here:
d:
ue:
- had to pio cycle 3 to get the nano to report
- Gary saw error flags on the 3m EC100. All looked okay yesterday, though the co2 levels are quite low – maybe nidas limit checking was setting flags. However, now I see no evidence of it at all in qctables. Found that it was reading all FF, but came back to good values with a power cycle.
- Apogee now mounted and reporting
- no Tsnows yet
uw:
- NR01 and wetness mounted and reporting
- Apogee now mounted and reporting
- no Tsnows yet
c:
- cu, ct are mounted, power and network cables connected, but not running
- cb, cl, cm mounted and running
- TRHs from 1–10m mounted and running
- snow nanos connected (but no inlets set up)
- flowcapts mounted, but not yet connected (need code to handle 2 such USB devices in one DSM)
- 4 pillows are now in place, two responding and two not yet connected
- Apogee now mounted and reporting
- no Tsnows yet
- need to figure out if sonic or EC150 should be mounted at 1.5m
Other:
- where to add webcam?
- add NR01 & wetness to qctables
- add second Victron to cl
Some tasks:
- take gravimetric sample
- take Leica readings
- read more serial numbers
- read guy tensions before leaving