Sept 26, 2012
Gordon and I investigated three stations with a bad TRH:
Stn 5: The TRH on serial port 5 at 2.5m was dead on arrival; no fan running; it had blown the 12V power fuse. We replaced it with a spare unit but used the original SHT sensor. Returned bad TRH to the base.
Stn 19: The TRH with mote id 10 at 0.5m was bad (but fan running). Tried replacing SHT but did not help. Returned bad TRH to base with original SHT.
Tower C: The TRH on serial port 6 at 1m had a bad cable. Replaced cable.