Dec 3, Playa motes at main site (near radiometers) and aux site (north of main) and Highland not reporting any data
Playa, 14:16 MST
Mote at main soil site is ID3: battery voltage = 12.5 V; reporting time information, but no soil data.
Mote at aux soil site is ID8: battery voltage = 11.4 V; disconnected gps, recycled power and data good.
However ID8 soon quit because battery voltage below 11.9 V (per JM).
Replaced aux battery w/ battery from main; now aux battery voltage = 13.5 V (perhaps 12.5 V was a typo).
Brought Mote ID3 and aux battery back to base
Highland, 15:54 MST
Soil mote battery voltage = 12.7 V.
Looking at data from motes:
Code Block |
---|
mote_dump |
showed continual reboot-like messages from the soil mote (ID22): "watchdog timer" and "sampling_mode=0", etc. No soil data. Yellow light was on solid.
Disconnected soil sensors and added them back sequentially. Data good until we connected Tsoil.
Replaced Tsoil w/ #0018 from Boulder (GM coated with fingernail polish in base).
Brought bad Tsoil back to base.