Taken mostly from qctables:

Radiometers: not getting rpile.in, tcase.in, others reporting (tried pushing scan i2c button, didn't fix) → swapped in radiometer with right id for longwave in, now all reporting.

NR01: updated PIC code and plugged into uw.  Isabel updated the configuration so data are expected.

Gsoil/qsoil/lambda: not yet plugged in (I think)plugged in with latest PIC code. Getting data from all, qsoil values are slightly negative. Is this a problem?

Tsoils: all reporting, data looks good.

...

TRH: all reporting (just replaced fuse + housing for 13m trh, it's reporting now but not yet making it to qctables), data looks good.

CSAT: no winds from ue 3m, ue 10m, c 5, 10, 15, 20m. Haven't done much looking into this yet. Looked at c 15m for a few minutes, lights in EC100 box are all green but not getting any data over the port (cu port 7). Will keep looking into the others.

EC150: no gas from all the ones listed above, plus uw 10m. All the co2 values from the EC150s that are reporting are clipped in qctables.

all reporting after I swapped the sonic head on 10m.c (and previous resetting of some EC100's using ECmon).  Some heads are intermittent, but I presume this will clear up in the field.

EC150:

  • all h2o reporting.  Some heads were blocked by foam padding.  (3m.uw died over friday night)
  • alll co2 reporting, but about half are clipped.  Hoping this will go away in the field.
  • Note that, in the ECmon reconfiguring, I noticed 2 EC100 boxes that were set to force Tirga to 25C.  I think these are all fixed now.

Pillows: working, needed reboot of cl. There are only 2 boxes connected.   Saturday: Now back down to 1 pillow; pillow 2 doesn't respond, even manually.  Don't know why notPillows: currently no data. Did these get unplugged? I know we were getting data from them earlier...

Flowcaps: getting data from 1m both flowcaps, not from 2m. Do we have a second flowcaps to stage, or is it just the 1m one?.  The second needed to have the power switch turned on its USB adaptor.  Both are now configured to the averaging we want (30/30/300).

Apogee IR: all reporting. Don't know if the values are ok because I don't know what the expected range is for this sensorRaw values look good, Steve is working on debugging the surface temp calculation.

Tsnows: Looks like there's one tsnow Currently plugged in at 0.5m on d, which is reporting. Nothing getting to qctables yet, I'll look at that.to d and ue.  (uw is done, but Chris is protecting the sensors so the cable doesn't reach.)  Looks good. 

Gps/chrony: finally started getting good GPS on uw, but just recently stopped getting good gps on ct. I'll look into it, see jira for more details. → ct fixed itself after I pulled the GPS antenna out to rest on the top of the dsm box.

Victrons: not staged, not planning to stage (actually want to stage at least one as part of a power drop test – Tony is building up power boxes for this)

Anything else I'm forgetting??