Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Replaced 15m cable (upper section) of the cabling to the 16m TRH due to corrosion at the coupling between the upper 15m and lower 5m sections.   Bottom 5m cable section should be replaced too.  Kurt taped the current coupling and inserted a drip loop.  Should be ok for a while.

Also replaced TRH external housing (shield, fan, firmware, etc), but used the original SHT sensor in this new housing.

Completed at 16m TRH has been missing since May 21 and acting up since as early as May 11.  Work today finalized by about 1pm LT.

On site: Kurt Knudson and Ned Patton