Here is a list of what I know about sensors at each site:
Site | Battery | Sonic | Krypton | Baro | TRH | Rad | Soil | Soil.aux | Precip | Shadowband | Prop |
---|---|---|---|---|---|---|---|---|---|---|---|
1 | ok | head off | not installed | ok | not installed | Rsw.in a bit strange, but went | ok | ok | not planned | SPN1 reporting 0 | ok |
2 | ok | ok | not installed | ok | not installed | Rsw.in<Rsw.out | ok | not planned | not planned | not planned | not planned |
3 | charging? | ok | <5mV | ok | not installed | ok | turned off? | not planned | no fluid | not planned | not planned |
4 | ok | ok | not installed | ok | not installed | ok | Qsoil bit high | not planned | reporting all 0 | not planned | not planned |
5 | ok | ok | <5mV | ok | problem -1<T<0 | Rsw.in high by x2 until 11/14 | Qsoil started being | Tsoil.4.4cm bad | not planned | not planned | not planned |
6 | ok | ok | <5mV | ok | not installed | turned off? | turned off? | turned off? | no fluid | not planned | ok |
7 | ok | ok | <5mV | ok | problem -1<T<0 | ok | ok | not planned | not planned | ok | not planned |