All are within 0.2 ohms of manufacturer values.  Except for one at 0.01 ohms, our values are higher.  <Might> be connectors, but 4-wire measurement should compensate.

Agar results (first row Sep 2010, second row Apr 2011):

ID

Sensor

Vheat

Vpile.on

Vpile.off

V63

Tau63

Lambda

1

200589

1236927

375

0

139

1943

666

 

 

1236402

375

0

139

1916

665

2

200590

1194264

314

0

116

1940

668

 

 

 

 

 

 

 

 

3

200236

1238958

313

0

116

1877

578

 

 

 

 

 

 

 

 

4

200391

1240328

313

0

116

2073

686

 

 

 

 

 

 

 

 

5

200239

1239719

470

0

174

1965

591

 

 

 

 

 

 

 

 

6

200592

1237441

407

0

150

2125

655

 

 

 

 

 

 

 

 

7

200241

1241515

376

0

139

1892

596

 

 

 

 

 

 

 

 

8

200242

1236806

407

0

150

2089

600

 

 

 

 

 

 

 

 

9

200243

1236372

438

0

162

1746

598

 

 

 

 

 

 

 

 

10

200234

1237511

281

0

104

1679

603

 

 

 

 

 

 

 

 

11

200238

1238329

439

0

162

1773

586