Gordon Nov 9
Chris substituted Paroscientific 6000 nano-barometers for the Vaisala PTBs at site 10 and at 1 meter on the main tower.
He will add a Paro 6000 to site 5 later today. Site 5 doesn't currently have a barometer, and he needs to modify the 1m boom.
The barometers were reporting at 1 Hz in some other units than millibars:
*000111.95841\r\n *000111.95840\r\n *000111.95839\r\n *000111.95844\r\n
I sent them the commands documented in http://wiki.eol.ucar.edu/sew/ISFS/SensorInformation/NanoParo, so that they report at about 13 Hz, in millibars.
With this modification, site 5 becomes a Aph station, rather than a Ah. On that DSM, I've left its hostname as Ah5, and just added the barometer to the catalog for Ah_DSMs.
Updated the XML on the servers (gully, flux and at EOL). On the servers, Ah5 is now an Aph_DSM.