Taken mostly from qctables:

Radiometers: not getting rpile.in, tcase.in, others reporting (tried pushing scan i2c button, didn't fix) → swapped in radiometer with right id for longwave in, now all reporting.

Gsoil/qsoil/lambda: not yet plugged in (Steve is updating PIC code on these sensors)

Tsoils: all reporting, data looks good.

Pressure: all reporting, no data in qctables because it's outside clip limits which are set for Gothic. Data looks ok in ncharts.

TRH: all reporting (just replaced fuse + housing for 13m trh, it's reporting now but not yet making it to qctables), data looks good.

CSAT: no winds from c 5, 10, 15, 20m. Haven't done much looking into this yet. Looked at c 15m for a few minutes, lights in EC100 box are all green but not getting any data over the port (cu port 7). Will keep looking into the others.

  • ue3m - sonic + gas lights are red. getting messages from sonic, but uvwtc, co2/h20, tirga/pirga are all nans. → after power cycle w/ pio lights are green + reporting winds + gas
  • ue10m - same behavior as ue3m, fixed same way
  • c5m - lights are green but no data (at all) on port. power cycle didn't help. note on ec100 that the pelican case it came out of had been labeled 'needs output reformat'
  • c10m - red for sonic, green for gas and power. gas data ok, nans for winds (but then why is gas data also missing on qctables?). sonic diagnostic is 16, or 'acquiring' → took sonic out of box to see if something was in the way, but no improvement.
  • c15m - see above
  • c20m - sonic light flashing red/green, others green. not sending any data to dsm.

EC150: no gas from all the ones listed above, plus uw 10m. All the co2 values from the EC150s that are reporting are clipped in qctables.

Pillows: currently no data. Did these get unplugged? I know we were getting data from them earlier...

Flowcaps: getting data from 1m flowcaps, not from 2m. Do we have a second flowcaps to stage, or is it just the 1m one? Probably just the one.

Apogee IR: all reporting. Raw values look good, Steve is working on debugging the surface temp calculation.

Tsnows: The one tsnow currently plugged in looks good. Are we planning to stage any of the others? Yes, once Chris updates the sensor ID numbers.

Gps/chrony: finally started getting good GPS on uw, but just recently stopped getting good gps on ct. I'll look into it, see jira for more details. → ct fixed itself after I pulled the GPS antenna out to rest on the top of the dsm box.

Victrons: not staged, not planning to stage (actually want to stage at least one as part of a power drop test – Tony is building up power boxes for this)

Anything else I'm forgetting??