Sept 26, 2012

Gordon and I investigated three stations with a bad TRH:

Stn 5: The TRH on serial port 5 at 2.5m was dead on arrival; no fan running; it had blown the 12V power fuse.  We replaced it with a spare unit but used the original SHT sensor.   Returned bad TRH to the base.

Stn 19: The TRH with mote id 10 at 0.5m was bad (but fan running).  Tried replacing SHT but did not help.  Returned bad TRH to base with original SHT.

Tower C: The TRH on serial port 6 at 1m had a bad cable.  Replaced cable.