Have started looking at the comparison between the various rain gauges.  In this analysis, I removed   There have been several major rain events, but not all sensors were working:

Date

understory

ott.pond

tb.pond

wxt.pond

wetness.pond

1 jun

ok

ok

wire stretched

misconfigured

ok

5-6 jun

plugged

ok

wire streched

misconfigured

ok

7 jun

plugged

ok

wire stretched

ok

ok

17-18 jun

plugged

ok

ok

ok

died

28 jun

branch hit

ok

ok

ok

ok

29 jun

ok

ok

ok

ok

ok

Daily storm totals (to nearest mm):

Date

understory

ott.pond

tb.pond

wxt.pond

6/1

32

41

40

 

6/2

3

1

1

 

6/6

3 (plugged)

18

 

 

6/7

1 (plugged)

50

 

13 (misconfig)

6/9

0

2

2

3

6/14

3

3

3

4

6/17

 

12

12

16

6/18

3 (plugged)

10

11

13

6/24

1

1

1

2

6/28

0

0

0

1

6/29

1 (hit)

18

19

21

 SUMMARY:

- Ott and siphoning tipping bucket agree very well (when totaled multiple days, agree to within 4%).

- WXT is high by about 30% (when totaled mulitple days)

- We don't have much good data from the understory gauge.

  • No labels