Did the round of s11, s10, s09:

base: with the dry weighing of the last sample in the oven, Round 1 is now complete.

s11: (check on Stephan's fix of our radiometer installation)

  • Stephan's fix looked good, with the screw anchor fully seated.  I adjusted the level just a smidge.
  • Based on Monday's meeting, downloaded all the raw data from April to my Mac, only to discover when I returned that all of the files were already on barolo.

s10: (routine check-up)

  • everything looked good.  Saw a deer walk by.
  • returned to the site, remembering my conversation with Chris about the occasional Victron outages.  Slightly reseated its USB cable on both ends and upgraded the firmware via the Victron connect app – both uploads were about 20 subversions newer.  The Victron cycled power during the second upload.  Everything seemed to come back normally.

s9: (routine)

  • just checked guy wire tension and radiometers.  All okay.