Data check showed all stations were operational and reporting data except for the NR01 from S9 (soils were still reporting data, but NR01 was reporting NAs).
Cleanup up the pod to access the spare NR01s.

Drove up to S9.  All cables to the NR01 and mote looked good. Did pull out and reseat cable to NR01, wetness sensor, and mote.
Connected to DSM with console.  Decided to reboot DSM, however nidas did not restart on boot. (not sure what caused this.
Eventually nidas was started manually, and all sensors started reporting including the NR01.
Also cleaned the windows on the NR01, and tightened one inner guy wire.


Also stopped by S10 to check it out.
Cleaned windows on NR01.
All guy wires tight.
Everything else looked good at S10