You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

On site: Golubieski, Semmer, Militzer, Maclean. Dave Gochis was
also at the tower site, installing soil sensors.

Reinstalled TRH transducers in ventilation units at all levels.

Started installing Licor 7500's. At 43 meters, S/N 1167, port ttyS17.

Measure total power draw at data system, prior to and after units 1167
was installed:

without 43m 7500

13.0 V

1.4 A

18.2 Watts

with 43m 7500

12.6 V

3.0 A

37.8 Watts

settled to

12.8 V

2.3 A

29.4 Watts

power difference

 

 

11.2 Watts

Measured power draw of the 43 meter 7500 only, with serial/power meter at
the adam:

43 meter 7500

12.4 V

.87 A

10.8 Watts

Tried to prepare units 813 and 1163 for installation at 30 meters,
but could not get them to boot and run. Red LED at circuit board
would stay on, or blink on and off. It is supposed to go off once
the unit is running. Measured 8 V at the end of 30 meter cable
with unit attached. Need to reduce this loss.

Installed S/N 1163, and 1164 at 30 and 16 meters, but witout data/power cables.

Licor 7500 S/N

level

status

1167

43 m

port 17, working

1163

30 m

not cabled

1164

16 m

not cabled

DC power supply in power enclosure is rated at 3 A, which will not
be large enough to drive system with 5 Licor 7500s.

Installed CRN1. Data is being received. Distance from top of CRN1 boom
to top of tower base plate is 22.38 meters. Chris said that per the
bubble level indicator the unit is quite level.

Distance from top of CRN1 boom to top of 16 meter sonic is 6.31 meters.
So the top of this sonic boom is at 22.38-6.31 = 16.03 meters.

Moved network switch from adam to power enclosure. Dave Gochis will
probably use one of the ethernet ports for his Tsoil CR1000.
After this switch, the fiber/copper media converter would not
connect - even after several power cycles of converter and switch.
Had to power cycle the media converter in the seatainer. This
may mean that the fiber network will not always come up after
a power outage.

Untaped pressure inlet (13:33 MST).

Updated NIDAS software on adam.

Installed anti-climb cage on tower.

  • No labels