• bring out 2-person shelter
  • bring out radiometer wipes
  • bring out Panduit ties
  • bring out more AA batteries (lithium?)
  • clean radiometers
  • check why Rsw.in is low on both NR01 and K&Z (presumably CVF4 is full of snow; maybe ask Dan and Eli to brush off NR01?)
  • move csat.1m.uw to 2m (or 4m?)
  • remove csat.1m.c? (since there already is a 2m.c – means sledding in CSAT and EC150 cases)
  • check/move other 1m csats to 2m
  • fix TRH.6m (it was unresponsive for most of 28 Dec, but came back – reseat cable?)
  • test mobile Tsnows (might already be done by Danny and Eli)
  • resecure Tsnow "base" mote (Chris was worried about cable tie breakage, so they are loose)
  • log snow pillow electronics serial numbers (just because; also Alpine Hydromet wants to know which one we unsealed)
  • debug TRH057 if time and/or bring back (would be done at RMBL using spare cables, DSM, and wstar. Goal is to determine whether TRH probe or housing or both are bad.  Symptom was Rfan reporting erratic values and initially fan appeared not to be working – high T values during day.  I bet it will appear to work fine now!)
  • bring back spare soils
  • No labels

2 Comments

  1. Revisit TRH.6m at site c. It's consistently a minimum and the standard deviations are large. This started around 14 Jan. You can see the pattern in QCtables. 

  2. Bring a spare ventilator for the K&Z