11:20 am MST, Nov 16
From phone conversation with John and Ling:
On site: John, Kurt, Ling
When they removed the SPN1, then the aux soils started coming in. Apparently a faulty I2C device can hang the mote. Mote ID 3 serves the aux soils and spn1 at this site.
They corrected the coefficients on the the pyranometers. Rsw.in and Rsw.out look good.
prep -D Rsw.in#1,Rsw.out#1 sock:porter 2010 11 16 18:26:12.4286 95 15.6 2010 11 16 18:26:17.4287 94.2 15.4 2010 11 16 18:26:27.4291 92.6 15.1 2010 11 16 18:26:32.4293 91.8 14.9
They forgot to bring the sonic head.
TRH013 is installed.
Shadow band radiometer is now working.
Cell modem signal levels: 28-30%, -93 dB