Dec 6, 14:20 Tom, Gordon

Installed Epply PSP 26224 downlooker. Made sure there were drip loops in the data cables for the downlooking radiometers.

PSP 16714 had been removed from this site yesterday due to a water leak.

26224 was a spare from the trailer, which needed an I2C address change. Previously it was address 85 (0x55), and I changed it to 91 (0x5b).

Sonic at this site has all wicks. Tom used datascope as a binocular.

At the site, noticed that main soil mote (ID12) was not reporting. Power cycled it.

Left at 14:40.