We did not have the opportunity to calibrate the pyrgeometers prior to the start of PCAPS, and therefore used old thermopile calibration factors for the Kipp & Zonen CG4 and Eppley PIR pyrgeometers.  These were subsequently recalibrated in the NOAA black body on March 8 & 10, 2011.  The following table lists multiplicative correction factors for Rpile outputs during the PCAPS field program.

Sensor

Location

Position

Pre-ops

Post-ops

Correction

 

 

 

uV-m^2/W

uV-m^2/W

pre/post

PIR 031980

Playa (1)

in

3.58

3.58

1.000

PIR 031976

Playa

out

3.93

3.74

1.051

PIR 031975

ABC (2)

in

3.97

3.98

0.997

PIR 031978

ABC

out

3.50

3.53

0.992

CG4 050824

Highland (3)

in

14.09

13.81

1.020

CG4 040740

Highland

out

7.85

7.76

1.012

CG4 030675

West Valley (4)

in

9.97

9.93

1.004

CG4 040741

West Valley

out

8.82

8.76

1.007

PIR 031979

East Slope (5)

in

3.99

3.81

1.047

PIR 031981

East Slope

out

3.69

3.66

1.008

CG4 100225

West Slope (6)

in

11.93

11.28

1.058

CG4 100226

West Slope

out

11.51

10.81

1.065

CG4 050823

Riverton (7)

in

9.32

9.21

1.012

CG4 030676

Riverton

out

11.27

11.21

1.005