9-Oct-12
personnel: JohnM, TomH.
Weather / Ops:
Winds diminished last night and remain low in the morning, possibly a good night/day for the science. Clear throughout the day with seasonally warm temps.
Ingest: Everything remained up throughout the day.
Flux Computer:
The Flux computer was still running cockpit ok this morning allowing status check. Tom Horst retreived it by 7:30 and took it to Boulder to be rebuilt before the next crew arrives.
Sensor Status / Issues:
The sensors continue to perform well and are coming in. Stations remain up and running. The issues noticed:
a2: 1m CSAT was not having any diag errors because the winds have been low. It was swapped by 10:15MST (16:15Z): s/n 833 removed, s/n 671 installed.
a8: TRH mote data now looking good. Since code update have not seen any \r\n hits.
Mote \r\n Issues: I don't see any/many of these in the data from other stations and now ID8 is running well. A more thorough examination confirmed that really only ID8 was a culprit. That particular mote was a replacement/repair brought up from Boulder after the site had some trh issues. The problem appears resolved.
To Do:
- Flux computer getting rebuilt in Boulder