17-Oct-12; ~8:00-9:00MST, 14:00-15:00Z
Reset Sampling rates from .78hz to speed up to 1hz on the sensors interfaced as serial devices on stations a1,a2,a3,a5,a6,c20,m21,m22. See table below. Those interfaced through the motes are and have been at 1hz.
NOTE: When/if someone changes a serial trh, this will likely need to be done.
Method:
Step |
Comment |
|
---|---|---|
ssh 'Stn' |
log into the station as numbered below. |
|
rs 'port#' |
Talk to the trh on the given port as noted below |
|
^U |
Ctrl-U enters the TRH's eeprom/command-mode |
|
TM0 -3125 |
Reset the clocking for the TRH sampling. |
|
EXT |
Exit the TRH command-mode |
|
^C |
exit rserial from talking to trh |
|
ds |
Wait for a few seconds and ^c and check the timing to be what you want |
|
Stn |
TRH |
Rserial port |
---|---|---|
a1 |
.5m, 2m |
rs1, rs5 |
a2 |
.5m, 2m |
rs1, rs5 |
a3 |
.5m, 2m |
rs5, rs6 |
a5 |
.5m, 2m |
rs1, rs5 |
a6 |
.5m, 2m |
rs1, rs5 |
c20 |
.5m, 1m, 1.5m, 2.5m |
rs2, rs6, rs7, rs9 |
m21 |
.5m, 1.5m, 2.5m, 3m, 4m |
rs2, rs8, rs11, rs13, rs15 |
m22 |
6m, 8m, 15m |
rs1, rs5, rs8 |
|
|
|