17-Oct-12; ~8:00-9:00MST, 14:00-15:00Z

Reset Sampling rates from .78hz to speed up to 1hz on the sensors interfaced as serial devices on stations a1,a2,a3,a5,a6,c20,m21,m22.  See table below.   Those interfaced through the motes are and have been at 1hz.

NOTE: When/if someone changes a serial trh, this will likely need to be done.  

Method:

Step

Comment

 

ssh 'Stn'

log into the station as numbered below.
GM has these automatically connect

 

rs 'port#'

Talk to the trh on the given port as noted below

 

^U

Ctrl-U enters the TRH's eeprom/command-mode
Observe it spit out the menu

 

TM0 -3125

Reset the clocking for the TRH sampling.
The -3125 speeds appears to be about right for 1-sec sampling

 

EXT

Exit the TRH command-mode
Observe it spit out some settings

 

^C

exit rserial from talking to trh

 

ds

Wait for a few seconds and ^c and check the timing to be what you want

 

Stn

TRH

Rserial port

a1

.5m, 2m

rs1, rs5

a2

.5m, 2m

rs1, rs5

a3

.5m, 2m

rs5, rs6

a5

.5m, 2m

rs1, rs5

a6

.5m, 2m

rs1, rs5

c20

.5m, 1m, 1.5m, 2.5m

rs2, rs6, rs7, rs9

m21

.5m, 1.5m, 2.5m, 3m, 4m

rs2, rs8, rs11, rs13, rs15

m22

6m, 8m, 15m

rs1, rs5, rs8