Comment: added later tasks

...

M Shot 4m boom angle (and reshot 2, 3, 5 to check).  Angles off since yesterday.

Later:

M replaced serializer in 10m CSAT (removed from MFO 853(?)).  This brought back the krypton.

A18 found that my splice of TRH lower had accumulated water and oxidized the Orange wire.  (The problem was because I couldn't find encapsulating heat shrink and had relied on normal heat shrink to protect the splice.)  I repaired, wrapped with electrician's tape, and stuffed the splice into the boom.  Now this works.

A11 Power had dropped.  Possible reason is that the power supply (that I replaced the fuse on yesterday that likely had blown during the lightning) is weak.  Another possibility is a bad battery (PCAPS leftover).  Another is the charge controller.  Removed all of this (and brought back to the base for testing).  In the meantime, stretched a DC power cable from M to A11's DSM.

Known issues still remaining:

A19 lower TRH still bad

A8 charge controller isn't keeping the battery up.  Battery voltage was only 12.0 at 1630, despite good sun in the afternoon.

A8 mote wasn't operating.  John should be able to fix in Boulder

A11 Tsoil.c has water-related dropouts (I think)

A11 Tsoil.g is dead and replacements didn't work (will keep on testing)