You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

24Jan2011 17: - 18: local Militzer/Horst

Conditions: beginning to cloud up, after sunset

Purpose: Reset Rad Mote ID from 11 to 9

Reprogrammed Rad mote using default id=9.   Was unable to get a reliable command interaction with the motes (10,11,21) at this station.   The base mote was at power level 0 instead of 4.   Gordon reset this from Boulder using the '+++', atpl4, atwr sequence, but we were still unable to get a good mote '#11id=9' command through to it, necessitating this change.

NOTE because the radiation mote id was different than expected in the xml, there will be a data gap in web-plots.. but that can be later merged in during post processing.

  • No labels