16 Jan: Militzer, Oncley

Purpose: TRH died at 2pm yesterday.  Came back to life early this AM, but we don't believe it.

0815: removed probe 19; fan ok

0821: installed 25.   DIN connector had corrosion on it.   Cleaned with ContactRenu as best possible (seems ok) and put some grease on probe pins.   Also put nail polish on sht pins where attached to board.

0823-0832: Rad: Rlw.in,Rsw.in,Rlw.out dessiccant all shot; replaced.   Cleaned water off incoming domes.

Conditions: Above freezing with snow cover on ground.   Some tufts of grass beginning to pop through snow.    Rain gauge has drained some fluid since our last visit.