24Jan2011, 10:30-12:30 local, Militzer/Horst

Conditions: mostly calm, upper 30's, clear

Purpose: RMY swap, Soil Samples, Update Mote Code

10:40 Rad Cleaned with Methanol, did not notice desiccant condition

10:35-10:45 Mote Software Updated version 2.4

11:00-11:27 Mast Lowered.   11:08 RMY swapped.   Previous sensor seemed ok and did not hear any bearing noise.   Swapped anyway.   Zeroed and 'boom-directioned to zero' on new sensor: consistent with previous unit.   It did seem as though the new sensor's prop was rotating and we didn't noticed a reported velocity.   It did start reporting speed with numbers about .4 so we assumed it is ok.   11:11 adn and aup while setting 'ZN' and 'BD'

11:15 Kh2O cleaned.   Voltage rose from 1.25 to 1.6 volts.

NOTE: Mast bolts on lowest joint were slightly loose; tightened them up.

ETI gauge was 2/3 full so we expect it to drain soon.  

11:30-12:30 Soil Samples taken first at the main and then auxiliary locations.   Container 1,0-3 and 1,3-6 were at main.   Containers 2,0-3 and 2,3-6 were at aux.